RU EN
Get tested

How CA-62 works: four diagrams

Why the marker appears at early stages, why a repeat test is needed and how to read the scale. The diagrams are qualitative, with no quantitative data except the reference points on the scale.

1. Where CA-62 in the blood comes from

NormalStem cells divideoccasionallyResolves on its ownBurst of division: inflammation,blood loss, pregnancyTumourConstant high secretion ofmembrane-protein vesiclesCA-62 level in the bloodbelow cut-offtemporarily aboveabove and stayscut-off 5,000 U/mL
CA-62 consists of membrane proteins with a distinctive N-glycosylation pattern typical of poorly differentiated cells. In healthy people their source is occasional division of stem cells. A temporary burst of division with inflammation, blood loss or pregnancy raises the level for a while. Tumour cells release these proteins in vesicles constantly and in large amounts, so the level is high and stays high.

2. Why the test is repeated after 4–8 weeks

repeat test4–8 weeks024681012weeks after the first testCA-62 level (schematic)cut-off 5,000firsttestInflammation, vaccination,blood loss — resolvesTumour — the elevationpersists
At the first test both cases may look the same. An elevation that resolves on its own falls below the cut-off by the repeat test, while a tumour-related one persists. With CA-62 above the cut-off and CRP < 10 mg/L, the cancer work-up starts without waiting for the repeat.

3. A signal of growth, not tumour mass

Share of cases detected (schematic)100%0in situIIIIIIIVstagesymptoms usuallyappearCA-62: high from early stages,declines only slightly laterConventional markers: risewith tumour mass
Conventional tumour markers enter the blood in proportion to tumour volume and turn positive mostly at late stages, when symptoms are already present. CA-62 reflects proliferative activity, so its sensitivity is already high in situ and at stage I–II and declines only slightly at later stages.

4. How to read the scale

102103104105106Luminescence signal (log scale)02,0004,0006,0008,00010,000CA-62, U/mLgreen zoneyellowabove cut-offcut-off 5,000≈ 10⁶ at 1,000 U/mLhundreds above 7,000 U/mL4,500 → 5,500 U/mL:signal ≈ 100× lower
In the competitive assay, luminescence falls as antigen concentration rises: in the order of 10⁶ at ~1,000 U/mL and hundreds above 7,000 U/mL. Between 4,500 and 5,500 U/mL the signal changes about a hundredfold, so close-looking values are not compared directly and the result is assessed against the cut-off. The curve is drawn from reference points; the exact calibration is in the instructions for use.

Back to the physicians section